To meet the customers' over-expected satisfaction , we have our strong team to provide our best overall service which includes marketing, sales, designing, production, quality controlling, packing, warehousing and logistics for Outdoor Disconnect Switch, Mv Transformer, 11kv Gis Switchgear, The team of our company with the use of cutting-edge technologies delivers impeccable quality products supremely adored and appreciated by our customers worldwide.
ODM Transformer Stations Exporter – RH- B series outdoor isolating switch/load switoh – Jonchn Detail:

Service environment

a) Air temperature: Maximum temperature: +75 °C; Minimum temperature:-45 °C
b) Humidity: Monthly average humidity 95%; Daily average humidity 90%
c) Altitude above sea level: Maximum installation altitude: 2500m
d) Ambient air not apparently polluted by corrosive and flammable gas, vapor etc.
e) No frequent violent shake

Features and benefits

●Compact design
●All steel parts either in stainless steel or hot-dip galvanized
●Solid and stable base frame
●Main contact with icing protection
●Insulators available in porcelain or alternatively in silicone
●Minimal sag for the line-connection thanks to the two fixed terminals
●Completely maintenance antirust AL alloy -Arc chamber
●Switching-off procedure without external arc
●Short circuit making capacity under specific conditions possible
●Fixing on the supporting structure either by clamping (free setting) or screwing (holes in thebase frame)
●Easy on-site installation and setting
●High reliability: up to 1000 cycles (depending on the making current)
●All conducting parts either silver, nickel or tin- plated
●Practically maintenance-free

Main technical specifications

Sheet 1

1

Sheet 2

2

Note: The FG type load break switch (disconnect switch) is equipped with stored energy released by fuse strike pins. The stored energy mechanism for the opening operation is released by fuse strike pins. The trip actuator is mounted on top of the fuse contact clip. The DIN type fuse is held in spring type contacts, secured by a tail lever. All the components are made of stainless steel, to prevent corrosion, have long live, and in the reset position. The trip lever is parked in an over-centre position.

Drawing and dimension

3


Product detail pictures:

ODM Transformer Stations Exporter –  RH- B series outdoor isolating switch/load switoh – Jonchn detail pictures

ODM Transformer Stations Exporter –  RH- B series outdoor isolating switch/load switoh – Jonchn detail pictures


Related Product Guide:

We emphasize progress and introduce new solutions into the market each year for ODM Transformer Stations Exporter – RH- B series outdoor isolating switch/load switoh – Jonchn , The product will supply to all over the world, such as: Kuwait, Cape Town, Norwegian, With the spirit of "high quality is our company's life; good reputation is our root", we sincerely hope to cooperate with customers from at home and abroad and hope to build a good relationship with you.