Our business puts emphasis over the administration, the introduction of talented staff, plus the construction of team building, attempting hard to boost the standard and liability consciousness of personnel customers. Our corporation successfully attained IS9001 Certification and European CE Certification of Sf6 Insulated Switchgear, Outdoor Compact Distribution Substation, Transformer Distribution, As a key enterprise of this industry, our corporation makes attempts to become a leading supplier, depending on the faith of expert excellent & throughout the world assistance.
ODM Outdoor Vaccum Circuit Breaker Manufacturers – JCM3 – Jonchn Detail:

Type and meaning

1

Normal working conditions

Ambient air temperature
The upper limit value is not more than + 40 ℃, the lower limit value is not less than -5 ℃;
The average value of 24 hours does not exceed + 35 ℃;
· installation site elevation does not exceed 200 OM.
· atmospheric conditions
Atmospheric relative humidity does not exceed 50% at ambient air temperature of + 40
℃: higher relative humidity can be achieved at lower temperatures, with the average
maximum of the wettest month
The average maximum relative humidity of the relative humidity is 90% , while the
average monthly minimum humidity for the month is + 25℃, taking into account
temperature changes that occur on the product surface
More than the provisions, users should consult with the factory.
protection level: 3.
Installation conditions: vertical or horizontal installation.
· installation type: Class III

Features

1. The ratings of circuit breakers are shown in the table below.
2, Distribution circuit breaker over-current release action characteristics see table 3, (for 30 ℃ each pole at the same time power characteristics).
3, Motor circuit breaker over-current release action characteristics see table 4, (for 30 ℃ each pole at the same time power
characteristics).
4, Circuit breaker short-circuit instantaneous protection current setting value see table 5, its accuracy is + 20% . The accessories are divided into four types: shunt release, under voltage release, auxiliary contact and alarm contact; external accessories include rotary handle operating mechanism, electric operating mechanism, etc.

Technical data

2
3
4

6
5


Product detail pictures:


Related Product Guide:

With a positive and progressive attitude to customer's interest, our company continuously improves our product quality to meet the needs of customers and further focuses on safety, reliability, environmental requirements, and innovation of ODM Outdoor Vaccum Circuit Breaker Manufacturers – JCM3 – Jonchn , The product will supply to all over the world, such as: Albania, Vietnam, Namibia, We insist on the principle of "Credit being primary, Customers being the king and Quality being the best", we are looking forward to the mutual cooperation with all friends at home and abroad and we will create a bright future of business.
Goods just received, we are very satisfied, a very good supplier, hope to make persistent efforts to do better.
5 Stars By Eleanore from Estonia - 2017.10.25 15:53
This company conforms to the market requirement and joins in the market competition by its high quality product, this is an enterprise that have Chinese spirit.
5 Stars By Ivan from India - 2017.08.21 14:13