Product description
● The main control board adopts a single chip microcomputer with an embedded operating system. The charging mode is divided into four types: automatic charging / fixed time / fixed amount / fixed power. RS-485 networking communication interface can be reserved, and optional GPRSnetworking mode is provided.
● 4.3-inch high resolution color touch screen display, with touch button operation, can set the charging mode
● The single-phase electronic watt-hour meter is used for electrical measurement and communicates with the main control board through the RS-485 interface.
● A contactless intelligent card reader is adopted to read the relevant information of the IC card and communicate with the main control board through the RS-485 interface. The background program of the main control board is used to identify the charger, record the user information and calculate the charging cost.
●Adopt line inlet switch with leakage protection function, and install emergency stop button.
●The shape adopts sheet metal and part ABS plastic structure, IP54 protection grade.
| Function Parameters/Device model | KW6230A-7/220 | KW6250A-7/220 | ||
| Product name | 7KWWall mounted ACcharging pile | 7KWFloor type AC charger | ||
| AC Input | AC input voltage range | AC220V±10% | ||
| Frequency range | 50±5 | |||
| Configuration andprotectioninformation | Output voltage range | AC220V | ||
| Maximum output current | 32 | |||
| Charging interface | National standard 7 core | |||
| Charging gun length | Customizable | |||
| Output current error | ≤±1% | |||
| Output voltage error | ≤±0.5% | |||
| The man-machine display | Color touch screen | |||
| Charging operation | Swipe card/scan code/password (customizable) | |||
| Measurement and billing | Time-sharing billing | |||
| Operating instructions | Power supply, charging, fault | |||
| Communication methods | Ethernet (GPRS optional) | |||
| Heat dissipation control | Natural cooling | |||
| Leakage protection | 30 | |||
| Protection grade | IP54 | |||
| Reliability | 50000 Hours | |||
| Workingcondition | Altitude | ≤2000 | ||
| Operatina ambienttemperature | -20-50(℃) | |||
| Storage ambient temperature | -40-70(℃) | |||
| Mean relative humidity | 5%-95% | |||
| Optional item | The above*options can be customized | |||